Home - Solutions - Power Grid Solutions - 20KV to 0.4kV Power Grid Transformer Solution

20KV to 0.4kV Power Grid Transformer Solution

Industry Pain Points

For conventional 35kV20kV//10kV to 0.4kV distribution grid projects, the core pain points are concentrated on low energy efficiency, poor safety, high maintenance cost and unstable power quality, which widely exist in urban and rural distribution networks, industrial park power supply and box substation scenarios:

1.1 High Operating Loss & Low Energy Efficiency

1.2 Single Product Adaptability & No Unified Matching Model

1.3 Simple Structure & Lack of Intelligent Monitoring

1.4 Poor Environmental Adaptability & Frequent Maintenance

1.5 Low Low-Voltage Power Supply Stability

Recommended Products (35kV/10kV to 0.4kV Fixed Matching Models)

We provide targeted high-efficiency transformer models for  10kV step-down to 0.4kV distribution scenarios, covering outdoor oil-immersed and indoor dry-type types, with complete capacity specifications to meet all conventional power grid distribution needs:

Outdoor Oil-Immersed Transformer (Main Model for Rural & Outdoor Grid)

Outdoor Oil-Immersed Transformer (Main Model for Rural & Outdoor Grid)

Core Models: S11-M, S13-M series 35/0.4kV & 10/0.4kV fully sealed oil-immersed transformers (Capacity: 30kVA–2500kVA)

Features: Low loss, fully sealed structure, rain and dust proof, low cost, suitable for outdoor pole-mounted, box substation and rural power grid step-down scenarios. S13 model further reduces energy loss and is a mainstream energy-saving upgrade model for power grids.

Indoor Dry-Type Transformer (Main Model for Urban & Indoor Grid)

Indoor Dry-Type Transformer (Main Model for Urban & Indoor Grid)

Core Models: SCB11, SCB13 series 35/0.4kV & 10/0.4kV epoxy resin cast dry-type transformers (Capacity: 50kVA–1600kVA)

Features: Oil-free, fireproof, explosion-proof, low noise, IP54 protection grade, with built-in temperature monitoring module. Suitable for urban indoor substations, commercial buildings, industrial workshops and densely populated areas.

Technical Solution

Aiming at 35kV/10kV step-down to 0.4kV terminal distribution grid, we adopt a simplified and efficient solution of fixed model matching + low-loss energy saving + intelligent monitoring + scenario adaptation:

Scenario-Based Fixed Model Matching

Unify outdoor scenarios with S11/S13 oil-immersed models and indoor closed scenarios with SCB11/SCB13 dry-type models. Fixed 35kV/10kV to 0.4kV voltage ratio, no customized adjustment required, realizing standardized grid matching.

Low-Loss Energy-Saving Optimization Technology

Adopt high-quality silicon steel sheet core and pure copper winding, optimize magnetic circuit structure. Compared with traditional old models, no-load loss is reduced by 40%-50%, load loss is reduced by 30%, adapting to long-term light-load operation of distribution networks.

Simplified Intelligent Operation & Maintenance

Configure independent temperature and load sensing devices for 35kV/0.4kV transformers. Support on-site display and remote data upload, realize overheating, overload and short-circuit fault early warning, reducing manual inspection pressure.

Safe & Environmentally Friendly Adaptation Technology

Oil-immersed models adopt fully sealed anti-leakage design; dry-type models adopt fully enclosed cast structure. Both adapt to -40℃~+45℃ ambient temperature, effectively solving environmental adaptation problems of terminal distribution transformers.

Terminal Power Quality Stabilization Technology

With built-in voltage regulation and three-phase balance optimization design, it automatically compensates terminal voltage drop, stabilizes 0.4kV low-voltage side power supply, and improves user power supply quality.

Project Cases

Industrial Park 10kV/0.4kV Distribution Project

Project Background: Industrial park terminal power supply has fluctuating load and high requirements for equipment stability.

Applied Model: SCB11-630kVA/10/0.4kV dry-type transformer

Project Effect: Strong overload resistance, stable low-voltage output, effectively avoiding equipment shutdown caused by voltage fluctuation, and reducing enterprise power consumption cost.

Installation Environment Description

This series of 35kV/10kV to 0.4kV distribution transformers are suitable for all conventional power grid terminal distribution scenarios with strong environmental adaptability:

Basic Environmental Parameters

Applicable altitude ≤2000m, ambient temperature -40℃~+45℃, relative humidity ≤95% (no condensation), wind resistance Grade 12, seismic resistance Grade 8.

Outdoor Installation Scenarios

S11/S13 oil-immersed transformers are applicable to rural pole-mounted installation, outdoor box substations, suburban distribution points. Fully sealed design prevents rain, dust and corrosion, suitable for open outdoor environments.

Indoor Installation Scenarios

SCB11/SCB13 dry-type transformers are applicable to indoor substations, power distribution rooms, commercial and industrial closed spaces. Oil-free and fireproof, no special fire isolation area required, saving installation space.

Cost Saving Analysis

Based on the full life cycle of10kV/0.4kV distribution transformers, the solution realizes obvious cost reduction in investment, energy consumption and maintenance:

1 Initial Investment Cost Saving

2 Energy Consumption Cost Saving

S13/SCB13 high-efficiency models greatly reduce light-load loss. Compared with traditional old transformers, the annual power loss cost of a single 800kVA transformer is saved by more than US$6,000, with long-term energy-saving benefit up to 30%-40%.

3 Operation & Maintenance Cost Saving

4 Lifecycle Benefit Improvement

5 Comprehensive Benefit Verification

Contact Us

Contact Us

Tel.: +86 158 3392 7003

E-mail: info@anshpower.com

WhatsApp: +86 158 3392 7003

Get in Touch

Get in Touch

Copyright @Hebei Ansheng Electric Power Equipment Co., Ltd. | Sitemap | Powered by Reanod